ICP 24V Transformer for RHS060L0XA0AAAA — 40 VA Control | Ships Today
ICP

ICP 24V Transformer for RHS060L0XA0AAAA — 40 VA Control | Ships Today

SKU: 1172619-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 24-volt control component (part #1172619) supplies the low-voltage 24V signal that operates the controls and reversing-valve circuit on the ICP/Tempstar/Heil RHS060L0XA0AAAA 5-ton heat pump. Rated at 40 VA, it steps line voltage down to the 24V needed to energize relays, the contactor coil, and the heat-pump control circuit. When this part fails, the unit goes completely dead at the thermostat — no cooling, no heating call, and no contactor pull-in — even though line voltage is present. A burned-out or shorted 24V control supply is a frequent no-response failure on heat-pump systems.

Specifications

Spec Value
Part Number 1172619
Type 24V Control / Step-Down
Brand ICP (Tempstar / Heil / Comfortmaker)
Secondary Voltage 24V
Rating 40 VA
Circuit Low-voltage control / reversing valve

Compatibility

Built for the ICP/Tempstar/Heil RHS060L0XA0AAAA heat-pump condensing unit and related ICP-family systems specifying a 24V, 40 VA control supply. Verify the secondary voltage and VA rating against the original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-access service panel.
  3. Document — Photograph the primary and 24V secondary wiring before disconnecting.
  4. Remove — Disconnect the leads, unfasten the mounting screws, and lift out the failed component.
  5. Install — Mount the new part and reconnect each lead to its matching terminal per your photo.
  6. Test — Restore power, confirm 24V on the secondary, and verify the unit responds to a thermostat call.

Signs You Need a Replacement

  • No response from the unit on a thermostat call
  • Contactor coil never pulls in despite line power
  • No 24V reading at the control secondary
  • Burnt smell or visible scorching on the windings

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP RHS060L0XA0AAAA — 40 VA Control | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP RHS060L0XA0AAAA — 40 VA Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP RHS060L0XA0AAAA — 40 VA Control | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.