Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 24V Control Transformer for WFML090C048A1 – 40VA Furnace Transformer | Ships Today
ICP

ICP 24V Control Transformer for WFML090C048A1 – 40VA Furnace Transformer | Ships Today

SKU: 1176944 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control transformer (ICP part number 1176944) supplies the 24-volt low-voltage power for the ICP / Heil / Tempstar WFML090C048A1 gas furnace. It steps the line-voltage primary down to a 24V secondary that energizes the thermostat, control board, gas valve, igniter circuit, and blower/inducer relays. When a transformer fails — typically from a shorted secondary, an overloaded accessory, or simple age — the furnace goes completely dead: no thermostat display, no call for heat, no blower. Replacing the transformer with the correct OEM part restores reliable 24V control power and protects the downstream control board.

Specifications

Spec Value
Part Number 1176944
Type Step-down Control Transformer
Brand ICP (Heil / Tempstar / Comfortmaker)
Secondary Voltage 24V
Rating 40VA (typical furnace control rating)
Fitment OEM replacement

Compatibility

Built for the ICP/Heil/Tempstar WFML090C048A1 furnace and other WFML-series and ICP-family furnaces using the same 24V control transformer. Verify your existing transformer's primary voltage tap and VA rating against the unit wiring diagram before installing.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker, then verify zero voltage at the transformer leads with a multimeter.
  2. Access – Remove the control/burner compartment service panel.
  3. Document – Photograph every primary and secondary wire and tap before disconnecting.
  4. Remove – Disconnect the line-voltage primary and 24V secondary leads, then unscrew the transformer from the panel.
  5. Install – Mount the new transformer, match the primary tap to your supply voltage, and reconnect the secondary per your photo.
  6. Test – Restore power, confirm 24V across the secondary, and run a heat call to verify normal operation.

Signs You Need a Replacement

  • Furnace is completely dead with no thermostat display.
  • No 24V present across the transformer secondary.
  • Transformer is hot, buzzing loudly, or smells burnt.
  • Repeated blown low-voltage fuse after clearing shorts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFML090C048A1 – 40VA Furnace Transformer | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFML090C048A1 – 40VA Furnace Transformer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFML090C048A1 – 40VA Furnace Transformer | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online