OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 24-volt control transformer supplies the low-voltage power that runs the thermostat, contactor coil, reversing valve solenoid, and control circuit on the ICP/Tempstar/Heil WCH3484GKB1 heat pump system. It steps line voltage down to a stable 24V Class 2 output rated at 40VA. When a transformer fails — usually from a shorted control wire, a stuck contactor coil drawing excess current, or age — the entire low-voltage side goes dead: no thermostat display, no contactor pull-in, and no system response to a call for heat or cool. A clicking or buzzing transformer, or one that runs hot to the touch, is a sign it's on the way out.
| Spec | Value |
|---|---|
| Type | Step-Down Control Transformer (Class 2) |
| Brand | ICP (Tempstar / Heil) |
| Secondary Voltage | 24V |
| Rating | 40VA |
| Application | Low-voltage control circuit |
| Related OEM Parts | 1172574, 1175622 |
| Fitment | OEM direct replacement |
Direct-fit for the ICP WCH3484GKB1 heat pump and related WCH3484 series units sold under ICP, Tempstar, Heil, and Comfortmaker. Confirm primary line voltage and the 24V/40VA rating against the unit's wiring diagram before installing.
Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.