This OEM 24-volt control transformer powers the low-voltage control circuit on the ICP/Tempstar/Heil WCH3484GKA2 heat pump — feeding the thermostat, contactor coil, reversing valve solenoid, and board. It steps line voltage down to a steady 24V Class 2 output rated at 40VA. A failed transformer kills the entire low-voltage side: a blank thermostat, a contactor that won't pull in, and a system that ignores every call for heat or cool. Buzzing, overheating, or a tripped internal fuse link are classic symptoms that the transformer needs replacement.

Specifications

Spec Value
Type Step-Down Control Transformer (Class 2)
Brand ICP (Tempstar / Heil)
Secondary Voltage 24V
Rating 40VA
Application Low-voltage control circuit
Related OEM Parts 1172574, 1175622
Fitment OEM direct replacement

Compatibility

Direct-fit for the ICP WCH3484GKA2 heat pump and related WCH3484 series units sold under ICP, Tempstar, Heil, and Comfortmaker. Confirm primary line voltage and the 24V/40VA rating against the unit's wiring diagram before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect. Verify zero voltage at the primary leads with a multimeter.
  2. Access — Remove the control panel cover to reach the transformer.
  3. Document — Photograph the primary (line) and secondary (24V) connections before removing anything.
  4. Remove — Disconnect the primary and secondary leads and unbolt the transformer.
  5. Install — Mount the new transformer and reconnect primary and secondary wiring per your photo.
  6. Test — Restore power, confirm 24V across the secondary, and verify the thermostat and contactor energize on a call.

Signs You Need a Replacement

  • Dead thermostat / no low-voltage power at the board.
  • Transformer buzzes, hums, or runs hot.
  • System won't respond despite line power present.
  • No 24V measured across the secondary with the unit powered.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WCH3484GKA2 — 40VA Class 2 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WCH3484GKA2 — 40VA Class 2 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WCH3484GKA2 — 40VA Class 2 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online