Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 24V Control Transformer for RHS150S0AA0AAAA — 40VA Reversing Valve Circuit | Ships Today
ICP

ICP 24V Control Transformer for RHS150S0AA0AAAA — 40VA Reversing Valve Circuit | Ships Today

SKU: 1172619 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 24-volt control transformer supplies low-voltage power to the control circuit of the ICP / Tempstar / Heil RHS150S0AA0AAAA heat pump, including the reversing-valve coil (PN 1172619), the 24V DPDT changeover relay (PN 1183814), and the reversing valve assembly (PN 1175367). The transformer steps line voltage down to a stable 24VAC at 40VA so the contactor, defrost board, and reversing valve receive clean, regulated control power. When a transformer fails, the entire low-voltage circuit goes dead — the system will not energize the contactor, the thermostat screen may go blank, and heating/cooling calls produce no response. Common failure causes are a shorted reversing-valve coil drawing excess current, a wiring short, or age-related insulation breakdown.

Specifications

Spec Value
Part Type Control Transformer
Brand ICP (Tempstar / Heil / Comfortmaker)
Secondary Voltage 24 VAC
Rating 40 VA
Related OEM Parts 1172619, 1183814, 1175367
Fitment OEM Replacement

Compatibility

Engineered for the ICP RHS150S0AA0AAAA heat pump and shared-platform RHS150-series units sold under the Tempstar, Heil, and Comfortmaker brands. Always confirm your existing transformer's primary and secondary voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the control-panel service cover.
  3. Document — Photograph every primary and secondary lead before disconnecting.
  4. Remove — Label and disconnect the transformer leads, then unbolt the transformer from the panel.
  5. Install — Mount the new transformer and reconnect each lead per your photo.
  6. Test — Restore power and confirm 24VAC across the secondary terminals.

Signs You Need a Replacement

  • No 24V output — contactor and reversing valve will not energize
  • Blank or dead thermostat with line power present
  • Repeatedly blown low-voltage fuse
  • Burnt smell or visible scorching on the transformer body

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP RHS150S0AA0AAAA — 40VA Reversing Valve Circuit | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP RHS150S0AA0AAAA — 40VA Reversing Valve Circuit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP RHS150S0AA0AAAA — 40VA Reversing Valve Circuit | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.