OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 24-volt control transformer supplies low-voltage power to the control circuit of the ICP / Tempstar / Heil RHS150S0AA0AAAA heat pump, including the reversing-valve coil (PN 1172619), the 24V DPDT changeover relay (PN 1183814), and the reversing valve assembly (PN 1175367). The transformer steps line voltage down to a stable 24VAC at 40VA so the contactor, defrost board, and reversing valve receive clean, regulated control power. When a transformer fails, the entire low-voltage circuit goes dead — the system will not energize the contactor, the thermostat screen may go blank, and heating/cooling calls produce no response. Common failure causes are a shorted reversing-valve coil drawing excess current, a wiring short, or age-related insulation breakdown.
| Spec | Value |
|---|---|
| Part Type | Control Transformer |
| Brand | ICP (Tempstar / Heil / Comfortmaker) |
| Secondary Voltage | 24 VAC |
| Rating | 40 VA |
| Related OEM Parts | 1172619, 1183814, 1175367 |
| Fitment | OEM Replacement |
Engineered for the ICP RHS150S0AA0AAAA heat pump and shared-platform RHS150-series units sold under the Tempstar, Heil, and Comfortmaker brands. Always confirm your existing transformer's primary and secondary voltage before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.