OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
These OEM definite-purpose contactors switch the high-voltage power to the compressor and condenser fan on your ICP Tempstar Heil RGS303HFAB0AGAA unit. Part 1171554 is a 2-pole 30A contactor and part 1183142 is a 3-pole 60A contactor, both with a 24V control coil energized by the thermostat or control board. When the coil pulls in, the contacts close and feed line voltage to the load. Contactors fail from contact pitting and welding caused by arcing, or from a burned-out coil. Typical symptoms include the outdoor unit not starting, a humming or chattering contactor, contacts that stick closed so the unit won't shut off, or visibly burned/pitted contacts. Installing the correct OEM contactor restores clean, reliable switching.
| Spec | Value |
|---|---|
| Part Number (2-Pole) | 1171554 – Contactor 2P 30A 24V |
| Part Number (3-Pole) | 1183142 – Contactor 3P 60A 24V |
| Type | Definite Purpose Contactor |
| Coil Voltage | 24V |
| Ratings | 30A / 60A |
| Brand | ICP / Tempstar / Heil / Comfortmaker |
| Fit | OEM Direct Replacement |
Direct-fit replacement for the ICP Tempstar Heil RGS303HFAB0AGAA unit and ICP-family equipment specifying contactor 1171554 (2P 30A) or 1183142 (3P 60A). Match the pole count, amp rating, and 24V coil on your existing contactor before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.