This OEM contactor listing covers the 24V-coil contactors used in the ICP Tempstar Heil RGS244HEEA0AAAA system, available in 2-pole 30A (1171554), 3-pole 40A (1172449), and 3-pole 60A (1183142) ratings. The contactor is the high-current switch that energizes the compressor and condenser fan motor when the 24V control circuit calls for cooling. Its contacts carry full line voltage, so they pit and burn over time. A failed contactor causes a no-start outdoor unit, chattering, or a system that runs continuously because the contacts have welded shut.

Specifications

Spec Value
Part Numbers 1171554, 1172449, 1183142
Type Definite-Purpose Contactor
Poles 2-Pole & 3-Pole options
Amp Ratings 30A / 40A / 60A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Application AC Compressor / Condenser Fan

Compatibility

Fits the ICP Tempstar Heil RGS244HEEA0AAAA and related units. Match the pole count and amp rating to the contactor you are replacing — 2-pole 30A, 3-pole 40A, or 3-pole 60A — and confirm the 24V coil.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the contactor.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Label and pull each terminal, unfasten the contactor from the bracket.
  5. Install — Mount the matching OEM contactor and reconnect each wire per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling call
  • Buzzing or chattering from the contactor
  • Pitted, burnt, or welded contacts
  • System runs nonstop because contacts won't open

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS244HEEA0AAAA — 30A/40A/60A 2 & 3 Pole | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS244HEEA0AAAA — 30A/40A/60A 2 & 3 Pole | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS244HEEA0AAAA — 30A/40A/60A 2 & 3 Pole | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online