Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Definite Purpose Contactor for RHS090H0BA0AAAA – 30/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Definite Purpose Contactor for RHS090H0BA0AAAA – 30/40A 24V Coil | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite purpose contactor is the main switching relay for the ICP/Heil/Tempstar RHS090H0BA0AAAA heat pump condensing unit. A 24-volt coil energized by the thermostat closes the line-voltage contacts to power the compressor and condenser fan motor. Offered as OEM parts 1178074 (30A) and 1178211 (40A), it handles the inrush and running load of the outdoor unit. Failing contactors cause no-start conditions, buzzing or chattering, and units that won't shut off — all traced to pitted, welded, or burned contacts and a worn coil.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar / Comfortmaker
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar RHS090H0BA0AAAA heat pump and comparable ICP-family condensing units using a 2-pole 24V coil contactor. Match the amp rating to your existing part — 1178074 for 30A, 1178211 for 40A.

Installation Guide

  1. Safety First – Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access – Remove the condenser service panel to reach the electrical compartment.
  3. Document – Photograph all wire positions before disconnecting.
  4. Remove – Transfer line, load, and 24V coil wires one at a time and unscrew the old contactor.
  5. Install – Mount the new contactor and reconnect each wire per your photo.
  6. Test – Restore power and confirm the contactor pulls in and the compressor and fan energize on a cooling call.

Signs You Need a Replacement

  • Outdoor unit hums but won't start
  • Loud buzzing or chattering at the contactor
  • Pitted, melted, or welded contacts
  • Compressor keeps running after the call ends

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS090H0BA0AAAA – 30/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS090H0BA0AAAA – 30/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS090H0BA0AAAA – 30/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online