Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Definite Purpose Contactor for RGS121HRAB0AAAA — 30A/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Definite Purpose Contactor for RGS121HRAB0AAAA — 30A/40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite purpose contactor is the electrically-controlled switch that energizes the compressor and condenser fan circuits in your ICP RGS121HRAB0AAAA system. When the thermostat calls for cooling, the 24V control coil pulls the contacts closed, sending line voltage to the high-amperage components. ICP supplies this assembly in both 30A (P/N 1178074) and 40A (P/N 1178211) ratings. A failing contactor is one of the most common HVAC service calls — symptoms include a system that won't start, an audible buzzing or chattering from the contactor, pitted or welded contacts, or a unit that runs continuously because the contacts have fused closed.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-Pole Definite Purpose
Brand ICP (Heil / Tempstar / Comfortmaker)
Contact Rating 30A / 40A
Coil Voltage 24V
Poles 2
Fitment OEM

Compatibility

Engineered for the ICP/Heil/Tempstar RGS121HRAB0AAAA gas furnace and condensing unit family. Confirm the amperage rating stamped on your existing contactor before ordering. Definite purpose contactors of matching pole count, coil voltage, and equal-or-greater amp rating are interchangeable.

Installation Guide

  1. Safety First — Disconnect power at the breaker and service disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the unit service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Note terminal positions, disconnect leads, and unscrew the old contactor from its mounting plate.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • System fails to start when the thermostat calls for cooling
  • Loud buzzing, humming, or chattering at the contactor
  • Visibly pitted, burned, or welded contacts
  • Compressor or fan runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121HRAB0AAAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121HRAB0AAAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121HRAB0AAAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online