Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor Set 30A & 40A 24V Coil for RGS150HSCB0AAAA — OEM | Ships Today
ICP

ICP 2-Pole Contactor Set 30A & 40A 24V Coil for RGS150HSCB0AAAA — OEM | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM 2-pole definite-purpose contactors for the ICP / Tempstar / Heil RGS150HSCB0AAAA packaged unit, covering both the 30-amp (part 1178074) and 40-amp (part 1178211) ratings with a 24V control coil. The contactor is the electrically operated switch that closes line voltage to the compressor and condenser fan motor whenever the thermostat calls for cooling. The 24V coil energizes, pulls the contacts closed, and passes 230V to the load. Pitted, burned, or chattering contacts are one of the most common reasons a unit won't start, hums, or trips on a hard start. These factory-spec contactors restore reliable, clean switching.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP RGS150HSCB0AAAA and related RGS-series packaged gas/electric units. Match your existing contactor's amp rating (30A or 40A) and confirm the 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the electrical/control service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unbolt the old contactor.
  5. Install — Mount the new contactor of matching amp rating, reconnect each wire per your photo.
  6. Test — Restore power, call for cooling, and confirm the coil pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Buzzing or humming from the contactor without the contacts closing
  • Pitted, blackened, or welded contacts
  • Compressor and fan fail to start on a cooling call
  • Intermittent operation or chattering under load

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HSCB0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HSCB0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HSCB0AAAA — OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online