Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RHS120L0AB0AAA — 30A/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RHS120L0AB0AAA — 30A/40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor switches line-voltage power to the compressor and condenser fan on the ICP Tempstar Heil RHS120L0AB0AAA heat pump. A 24V signal from the thermostat energizes the coil, pulling the contacts closed to start the outdoor unit. Available in 30A (P/N 1178074) and 40A (P/N 1178211) ratings. Pitted, burned, or chattering contacts are a leading cause of no-cooling and no-heat calls — when the contactor won't pull in, the compressor stays off even though the thermostat is calling.

Specifications

Spec Value
Part Numbers 1178074 (30A) / 1178211 (40A)
Type 2-Pole Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Contact Rating 30A / 40A
Coil Voltage 24V
Poles 2

Compatibility

Fits the ICP Tempstar Heil RHS120L0AB0AAA heat pump and related RHS120-series condensing units. Match the amp rating to your original contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or unbolt the old contactor after labeling leads.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly.

Signs You Need a Replacement

  • Compressor won't start despite a call from the thermostat
  • Buzzing or chattering at the outdoor unit
  • Pitted, welded, or burned contacts
  • Coil fails to pull the contacts closed on 24V

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS120L0AB0AAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS120L0AB0AAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS120L0AB0AAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.