Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RHS102L0CB0AAA — 30A/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RHS102L0CB0AAA — 30A/40A 24V Coil | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor (parts 1178074 at 30A and 1178211 at 40A) is the heavy-duty switch that energizes the compressor and condenser fan motor on your ICP RHS102L0CB0AAA heat pump. When the thermostat calls, the 24V coil closes the contactor and sends line voltage to the compressor. Because the contacts arc on every cycle, contactors are among the most common HVAC service items. A failing contactor shows up as a unit that won't start, loud chattering or buzzing, contacts welded shut so the compressor never shuts off, or visibly pitted and burnt contact points. A fresh OEM-rated contactor restores clean, positive switching and protects the compressor from chattering and low-voltage damage.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30 Amp / 40 Amp
Coil Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil RHS102L0CB0AAA heat pump and compatible RHS102-series condensing units using a 2-pole, 24V-coil contactor. Match your unit's required amp rating (30A or 40A) and confirm coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the contactor.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Label and transfer wires one at a time, then unscrew the old contactor from its mounting.
  5. Install — Mount the new contactor and reconnect line, load, and 24V coil leads exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a thermostat call with no chatter.

Signs You Need a Replacement

  • Compressor and condenser fan won't start on a cooling/heating call
  • Loud chattering or buzzing at the contactor
  • Pitted, burnt, or welded contact points
  • Contactor stuck closed, leaving the compressor running nonstop

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS102L0CB0AAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS102L0CB0AAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS102L0CB0AAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera