Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RHS102L0AB0AAAA — 30/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RHS102L0AB0AAAA — 30/40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This 2-pole definite-purpose contactor is the high-voltage switch that powers the compressor and condenser fan on your ICP RHS102L0AB0AAAA heat pump. When the thermostat calls for cooling or heating, the 24V coil pulls the contacts closed and sends line voltage to the compressor. Contactors are one of the most common HVAC failure points — the contacts pit and burn from arcing, ants and debris jam the plunger, and the coil burns out. A failed contactor causes a unit that hums but won't start, a chattering buzz, or a condenser that runs continuously even after the call ends.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-Pole Definite Purpose
Brand ICP (Tempstar / Heil)
Amperage 30A / 40A
Coil Voltage 24V
Poles 2

Compatibility

Direct fit for the ICP/Tempstar/Heil RHS102L0AB0AAAA and other RHS102 series units. Choose the 30A or 40A rating to match your existing contactor's amp rating.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical service panel.
  3. Document — Photograph every line-voltage and 24V coil wire before removing anything.
  4. Remove — Transfer wires one at a time, or label them, then unbolt the old contactor.
  5. Install — Mount the new contactor, reconnect the line leads (L1/L2/T1/T2) and the 24V coil leads per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a thermostat call.

Signs You Need a Replacement

  • Unit hums but compressor and fan won't start
  • Loud chattering or buzzing at the contactor
  • Pitted, burned, or welded contacts
  • Condenser keeps running after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS102L0AB0AAAA — 30/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS102L0AB0AAAA — 30/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS102L0AB0AAAA — 30/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online