Overview

This is a genuine OEM 2-pole definite purpose contactor (part #1178074) for the ICP/Tempstar/Heil RHS060H0BB0AAAA heat pump. The contactor is the electromechanical relay that switches line voltage to the compressor and condenser fan motor whenever the 24V control circuit calls for cooling or heating. Rated for 30 amps per pole with a 24-volt coil, it carries the full load current of the outdoor unit. Pitted, burned, or chattering contacts are one of the most common no-cool service calls — failed contactors prevent the compressor from energizing or cause it to short-cycle.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor, 2-Pole
Brand ICP (Tempstar / Heil / Comfortmaker)
Amp Rating 30A
Coil Voltage 24V
Poles 2

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil RHS060H0BB0AAAA heat pump condensing unit and other models in the RHS060 family that originally shipped with contactor 1178074. Always confirm the amp and coil voltage against the part being replaced.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph all wire positions before disconnecting.
  4. Remove — Label and remove the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor energizes.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts
  • Loud humming, buzzing, or chattering at the contactor
  • Compressor and condenser fan won't start on a cooling call
  • Contacts stay stuck closed and the unit won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS060H0BB0AAAA — 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS060H0BB0AAAA — 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS060H0BB0AAAA — 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online