Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RHH120H0EA0AAAA — 30A/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RHH120H0EA0AAAA — 30A/40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole definite-purpose contactor for the ICP / Heil / Tempstar RHH120H0EA0AAAA heat pump. The contactor is the electrically operated switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heating. When the 24-volt coil is energized, the contactor pulls its contacts closed and sends line voltage to the outdoor unit. This part is offered in 30-amp (OEM 1178074) and 40-amp (OEM 1178211) ratings, both with a 24V control coil. Pitted, burned, or chattering contacts are one of the most common causes of an outdoor unit that hums but won't start, trips the breaker, or runs intermittently.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Poles 2-Pole
Coil Voltage 24V
Contact Rating 30A / 40A FLA
Brand ICP / Heil / Tempstar
Fits Model RHH120H0EA0AAAA

Compatibility

Designed as a direct-fit replacement for the ICP-family RHH120H0EA0AAAA heat pump and shared platforms sold under the Heil, Tempstar, and Comfortmaker labels. Confirm your existing contactor's pole count, coil voltage (24V), and amp rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the condensing unit's electrical access panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting anything.
  4. Remove — Label and disconnect the wires, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor, reconnect line (L1/L2), load, and the two 24V coil leads exactly per your photo.
  6. Test — Restore power and call for cooling; confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor won't start.
  • Visible pitting, melting, or carbon burning on the contacts.
  • Contacts that stick closed so the unit won't shut off.
  • Clicking or chattering at the contactor when the thermostat calls.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH120H0EA0AAAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH120H0EA0AAAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH120H0EA0AAAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.