Overview

This genuine ICP OEM 2-pole contactor is the factory switching relay for the RGS180HSEA0AAAA system, available in 30-amp (part 1178074) and 40-amp (part 1178211) ratings, both with a 24-volt control coil. A contactor is the electrically operated switch that closes the high-voltage circuit to the compressor and condenser fan when the 24V thermostat signal energizes its coil. Over time the contact points pit, arc, and corrode, causing chattering, welded contacts that won't shut off, or no power to the outdoor unit at all. Replacing a worn 2-pole contactor restores clean, reliable switching and protects downstream motors and the compressor.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-Pole Contactor
Brand ICP (Tempstar / Heil)
Contact Rating 30A and 40A
Coil Voltage 24V
Poles 2
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS180HSEA0AAAA system. Choose the 30A or 40A rating to match your original contactor; both share the standard 24V coil used across this equipment family.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel covering the contactor.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unbolt the old contactor from its bracket, and remove it.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and drops out cleanly.

Signs You Need a Replacement

  • Loud chattering or buzzing from the contactor
  • Contacts welded closed — outdoor unit runs nonstop
  • Pitted, burned, or blackened contact points
  • Compressor or condenser fan gets no power on a cooling call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS180HSEA0AAAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS180HSEA0AAAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS180HSEA0AAAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online