This is the genuine OEM 2-pole, 24-volt-coil definite-purpose contactor for the ICP / Tempstar / Heil RGS150SFAA0AKAA, available in 30-amp (part number 1178074) and 40-amp (part number 1178211) ratings. The contactor is the electromechanical switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. The 24V coil pulls the contacts closed to pass line voltage to the load. Contactors are one of the most common failure points in any outdoor unit — pitted or welded contacts, a chattering or open coil, and insect/debris intrusion all cause hard-start, no-start, or continuous-run conditions.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-pole definite-purpose contactor
Brand ICP (Tempstar / Heil)
Coil Voltage 24V
Poles 2
Contact Rating 30A or 40A (select to match)
Fitment OEM replacement

Compatibility

Fits the ICP RGS150SFAA0AKAA and equivalent Tempstar, Heil, and Comfortmaker units. Match the amp rating (30A vs 40A) to the contactor currently installed or to the unit's data plate before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the service/electrical panel on the outdoor unit.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Burnt, pitted, or welded-together contacts
  • Buzzing or chattering coil
  • Compressor/fan won't start, or won't shut off
  • Visible insect nests or corrosion across the contacts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150SFAA0AKAA — 30A & 40A 24V OEM Options | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150SFAA0AKAA — 30A & 40A 24V OEM Options | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150SFAA0AKAA — 30A & 40A 24V OEM Options | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online