This OEM 2-pole contactor switches line voltage to the compressor and condenser fan in your ICP RGS150LRAA0AGAA package unit. When the thermostat calls for cooling, the 24V coil pulls in the contacts and energizes the load. Available in 30A (OEM 1178074) and 40A (OEM 1178211) ratings to match your exact unit, both with a 24V control coil. Contactors are a high-wear item — the contacts pit and burn over thousands of cycles, leading to chattering, dropped calls, or a unit that won't start at all.

Specifications

Spec Value
Part Number(s) 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Poles 2-Pole
Rating 30A / 40A
Coil Voltage 24V

Compatibility

Direct fit for the ICP RGS150LRAA0AGAA package gas/electric unit and ICP-family equipment sold under Tempstar, Heil, and Comfortmaker that use a 2-pole, 24V-coil contactor. Match the amp rating (30A or 40A) and coil voltage to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and confirm zero voltage across the line terminals with a multimeter.
  2. Access — Remove the electrical access panel to expose the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew the contactor from the rail or panel.
  5. Install — Mount the new contactor, land each wire on the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Loud buzzing or chattering when the system starts
  • Pitted, burnt, or welded contacts
  • Compressor and fan fail to energize on a cooling call
  • Intermittent operation or repeated breaker trips

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150LRAA0AGAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150LRAA0AGAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150LRAA0AGAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online