Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RGS150HRAA0AGAA — 24V Coil 30A/40A | Ships Today
ICP

ICP 2-Pole Contactor for RGS150HRAA0AGAA — 24V Coil 30A/40A | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor is the electrically operated switch that energizes the compressor and condenser fan circuits in your ICP RGS150HRAA0AGAA system. A 24-volt signal from the thermostat or control board pulls in the contactor coil, closing the line-voltage contacts that feed the load. This listing covers the genuine factory replacements 1178074 (2-pole, 30A, 24V coil) and 1178211 (2-pole, 40A, 24V coil). Failed contactors are one of the most common no-cool service calls — pitted, welded, or chattering contacts prevent the unit from starting or cause it to run intermittently.

Specifications

Spec Value
Part Number 1178074 / 1178211
Type 2-Pole Definite Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Coil Voltage 24V
Contact Rating 30A (1178074) / 40A (1178211)
Poles 2
Fitment OEM

Compatibility

Engineered for the ICP / Heil / Tempstar RGS150HRAA0AGAA and shared across many ICP-family condensing units and gas furnaces using a 24V control circuit. Confirm coil voltage and amp rating against the contactor currently installed.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the control box.
  3. Document — Photograph all wires before disconnecting.
  4. Remove — Label and transfer line, load, and 24V coil leads; unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor/fan energize.

Signs You Need a Replacement

  • Unit won't start or hums without engaging
  • Burned, pitted, or welded contacts
  • Chattering or buzzing at the contactor
  • Intermittent cooling or tripped breakers

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HRAA0AGAA — 24V Coil 30A/40A | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HRAA0AGAA — 24V Coil 30A/40A | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HRAA0AGAA — 24V Coil 30A/40A | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online