Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RGS150HDAA0AGAA — 30A & 40A 24V OEM | Ships Today
ICP

ICP 2-Pole Contactor for RGS150HDAA0AGAA — 30A & 40A 24V OEM | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM 2-pole definite-purpose contactor for the ICP / Tempstar / Heil RGS150HDAA0AGAA system, available in 30-amp (part 1178074) and 40-amp (part 1178211) ratings with a 24-volt coil. The contactor is the electrically operated switch that closes the line-voltage circuit to the compressor and condenser fan whenever the 24V control signal energizes its coil. Pitted, welded, or chattering contacts are one of the most common causes of a unit that won't start, trips on startup, or buzzes loudly — replacing the contactor restores clean, reliable switching.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite-Purpose Contactor
Poles 2-Pole
Coil Voltage 24V
Amp Rating 30A / 40A
Brand ICP / Tempstar / Heil
Fit Genuine OEM

Compatibility

Fits the ICP-built RGS150HDAA0AGAA and many shared Tempstar, Heil, and Comfortmaker models. Select the amp rating that matches your original contactor — verify pole count, coil voltage (24V), and amp rating against the old part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect each wire, unscrew the old contactor from its mount.
  5. Install — Mount the new contactor, reconnect line, load, and coil wires exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts
  • Loud humming, buzzing, or chattering when energized
  • Compressor or condenser fan fails to start
  • Intermittent operation or visible arcing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HDAA0AGAA — 30A & 40A 24V OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HDAA0AGAA — 30A & 40A 24V OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HDAA0AGAA — 30A & 40A 24V OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online