Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RGS121HTCB0AAA — 30A/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RGS121HTCB0AAA — 30A/40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor is the electrical switch that powers the compressor and condenser fan motor on your ICP Tempstar/Heil RGS121HTCB0AAA furnace and matched cooling system. Energized by a 24-volt control signal from the thermostat, the contactor's coil pulls the contacts closed to deliver line voltage to the high-current loads. Available in 30-amp (OEM 1178074) and 40-amp (OEM 1178211) ratings, both with a 24V coil. A contactor that has burned, pitted, or welded contacts is one of the most common causes of a system that won't start, hums but won't engage, or trips the breaker. Replacing it is an inexpensive fix that restores reliable switching.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-Pole Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30A or 40A
Coil Voltage 24V
Poles 2
Fitment OEM Replacement

Compatibility

Engineered for the ICP Tempstar/Heil RGS121HTCB0AAA and other RGS-series gas furnaces and matched condensing units that use a 2-pole 24V-coil contactor. Confirm your existing contactor's amp rating (30A vs 40A) and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the control compartment.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil wires; unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and the system runs.

Signs You Need a Replacement

  • System hums but the compressor/fan won't start
  • Visibly burned, pitted, or melted contacts
  • Chattering or buzzing from the contactor
  • Contacts welded closed so the unit won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121HTCB0AAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121HTCB0AAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121HTCB0AAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR