Overview

Genuine OEM 2-pole definite purpose contactor for the ICP / Heil / Tempstar RGS121HRBB0AAAA. Available in 30 amp (part #1178074) and 40 amp (part #1178211) ratings, both with a 24V coil. The contactor is the electrically controlled switch that energizes the compressor and condenser fan when the thermostat calls for cooling. When the 24V coil is energized, the contacts close and pass line voltage to the load. Pitted, burned, or chattering contacts are one of the most common causes of a unit that won't start, runs intermittently, or trips breakers.

Specifications

Spec Value
30A Part Number 1178074 (Contactor 2P 30A 24V)
40A Part Number 1178211 (Contactor 2P 40A 24V)
Type Definite Purpose Contactor
Poles 2-Pole
Coil Voltage 24V
Contact Rating 30A / 40A
Brand ICP / Heil / Tempstar
Fit OEM

Compatibility

Fits the ICP-family RGS121HRBB0AAAA and other units using a 2-pole 24V-coil contactor. Match the amperage (30A or 40A) to your original contactor's rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel to expose the contactor.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Label and disconnect line, load, and 24V coil wires, then unscrew and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Chattering or buzzing when the coil energizes
  • Unit won't start or runs intermittently on a cooling call
  • No 24V pull-in or visibly damaged coil

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121HRBB0AAAA — 30A & 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121HRBB0AAAA — 30A & 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121HRBB0AAAA — 30A & 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online