Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RGS121HFBB0AAAA — 30A & 40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RGS121HFBB0AAAA — 30A & 40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite-purpose contactor is a 2-pole switch with a 24V control coil that energizes the outdoor compressor and condenser fan circuits associated with the ICP Tempstar/Heil RGS121HFBB0AAAA system. Two amperage options are covered: part 1178074 rated 2-pole 30A and part 1178211 rated 2-pole 40A, both with a 24-volt coil. When the thermostat calls for cooling, the low-voltage coil pulls the contacts closed to deliver line voltage to the load. Pitted, welded, or chattering contacts cause hard starts, no-cooling calls, and buzzing — a fresh contactor restores clean, reliable switching.

Specifications

Spec Value
Part Numbers 1178074 (2P 30A), 1178211 (2P 40A)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30A (1178074) / 40A (1178211)
Coil Voltage 24V
Fits Model RGS121HFBB0AAAA
Fit OEM Direct Replacement

Compatibility

Fits the ICP/Tempstar/Heil RGS121HFBB0AAAA and related units calling for a 2-pole 24V-coil contactor. Match your existing contactor's amperage (30A or 40A) and confirm a 24V coil before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker and verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel to reach the contactor.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect the wires, unfasten the old contactor, and lift it out.
  5. Install — Mount the new contactor and reconnect each wire exactly as photographed.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly with the compressor and fan running normally.

Signs You Need a Replacement

  • System won't start or only runs intermittently on a cooling call
  • Loud buzzing, humming, or chattering from the contactor
  • Pitted, burned, or welded-together contacts
  • Visible arcing, melted housing, or carbon scoring

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121HFBB0AAAA — 30A & 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121HFBB0AAAA — 30A & 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121HFBB0AAAA — 30A & 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online