Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RGS121HEBB0AAAA — 30A & 40A 24V OEM | Ships Today
ICP

ICP 2-Pole Contactor for RGS121HEBB0AAAA — 30A & 40A 24V OEM | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

These are genuine OEM 2-pole definite purpose contactors for the ICP / Tempstar / Heil RGS121HEBB0AAAA system, available as the 30-amp 1178074 (CONTACTOR 2P 30A 24V) or the 40-amp 1178211 (CONTACTOR 2P 40A 24V). Both use a 24-volt control coil. A contactor is the heavy-duty relay that switches line voltage to the compressor and condenser fan motor whenever the 24V control circuit energizes its coil. Over years of cycling, the silver contacts pit, weld, or burn, and the coil can fail — leaving the unit dead, stuck running, or buzzing. Select the amp rating that matches the contactor currently installed in your equipment.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor, 2-Pole
Poles 2
Contact Rating 30A or 40A
Coil Voltage 24V
Brand ICP / Tempstar / Heil / Comfortmaker
Fits Model RGS121HEBB0AAAA
Fitment Direct OEM replacement

Compatibility

Direct-fit replacement for the ICP RGS121HEBB0AAAA system and related Tempstar, Heil, and Comfortmaker units using a 2-pole, 24V-coil contactor. Confirm whether your unit uses the 30A or 40A rating and that the coil is 24V before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage at the contactor line terminals with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect each wire, unscrew the old contactor, and lift it out.
  5. Install — Mount the new contactor and reconnect line, load, and coil leads exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan energize without chatter.

Signs You Need a Replacement

  • Compressor and condenser fan will not start on a cooling call.
  • Loud buzzing or chattering from the contactor.
  • Pitted, blackened, or welded contacts that stick closed.
  • Unit runs continuously and will not shut off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121HEBB0AAAA — 30A & 40A 24V OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121HEBB0AAAA — 30A & 40A 24V OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121HEBB0AAAA — 30A & 40A 24V OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online