This OEM 2-pole definite-purpose contactor for the ICP/Tempstar/Heil RGS121HDAB0AAAA is available in a 30-amp version (part 1178074) and a 40-amp version (part 1178211), both with a 24V control coil. The contactor is the high-voltage switch that energizes the compressor and condenser fan when the 24V thermostat signal closes the coil. Two poles break both legs of the line voltage for safe, reliable switching. Over time the contact points pit, arc, and weld from the inrush current — a failing contactor causes a system that won't start, chatters, or won't shut off because the contacts have fused closed. Match the amp rating to the contactor you are replacing.
| Spec | Value |
|---|---|
| Part Number | 1178074 (30A) / 1178211 (40A) |
| Type | 2-Pole Definite Purpose Contactor |
| Brand | ICP / Heil / Tempstar / Comfortmaker |
| Contact Rating | 30A or 40A |
| Coil Voltage | 24V |
| Poles | 2 |
| Application | AC Compressor / Condenser Fan Switching |
| Fitment | OEM Direct Replacement |
Designed for the ICP RGS121HDAB0AAAA and the Tempstar, Heil, and Comfortmaker systems using a 2-pole 24V-coil contactor. Verify both the amp rating and OEM part number (1178074 or 1178211) against your existing contactor before ordering.
Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.