Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RGS102LSBA0AAA — 30A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RGS102LSBA0AAA — 30A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole contactor (OEM part #1178074) is the electromagnetic switch that energizes the high-voltage load circuit in your ICP RGS102LSBA0AAA system. Rated at 30 amps with a 24V control coil, it uses a low-voltage signal from the control board to pull in two sets of line-voltage contacts. Contactors are a high-wear component: every call for operation slams the contacts closed, so over thousands of cycles the contact faces pit, burn, and weld. Common failure symptoms include a buzzing or chattering contactor, contacts that stick closed (unit won't shut off), or contacts that won't pull in at all (unit won't start). Replacing a worn contactor restores reliable switching and protects downstream components from arcing damage.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Directly fits the ICP/Heil/Tempstar RGS102LSBA0AAA. The 2-pole, 30A, 24V-coil configuration is also a common service part across many ICP-family condensing units and air handlers — always confirm amperage, pole count, and coil voltage against the contactor currently installed before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and pull the local disconnect. Verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph every wire and terminal location before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil leads; unscrew the contactor from its mounting bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly as photographed.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no buzzing and that the unit cycles normally.

Signs You Need a Replacement

  • Loud buzzing, humming, or chattering from the contactor
  • Pitted, blackened, or welded contact points
  • Unit won't start, or won't shut off after the call ends
  • Visible arcing or a burnt-electrical smell at the contactor

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102LSBA0AAA — 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102LSBA0AAA — 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102LSBA0AAA — 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online