Overview

This is a genuine OEM 2-pole definite-purpose contactor (part number 1178074) for the ICP/Heil/Tempstar RGS102HFCB0AAA system. The contactor is the electrically-operated switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. It carries a 30-amp current rating across two poles and uses a 24-volt control coil energized by the low-voltage circuit from the control board. When the coil pulls in, the contacts close and line voltage passes through to the outdoor unit; when the call ends, a spring opens the contacts. Worn, pitted, or chattering contacts are one of the most common causes of a unit that will not start, hums but does not run, or trips the breaker.

Specifications

Spec Value
OEM Part Number 1178074
Type Definite-Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Fits Model RGS102HFCB0AAA

Compatibility

Designed as a direct OEM replacement for the ICP/Heil/Tempstar RGS102HFCB0AAA and other systems that specify part number 1178074. Always confirm the existing contactor's pole count, amp rating, and coil voltage against your old part before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph all wire positions before disconnecting anything.
  4. Remove — Note line, load, and 24V coil terminals; transfer one wire at a time, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the unit runs.

Signs You Need a Replacement

  • Compressor hums but will not start, or the unit fails to start at all.
  • Visible pitting, burning, or melted plastic on the contacts.
  • Buzzing, chattering, or a stuck contactor that won't drop out.
  • Breaker trips or ants/debris are bridging the contacts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102HFCB0AAA — 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102HFCB0AAA — 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102HFCB0AAA — 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.