This is the genuine OEM 2-pole definite purpose contactor for the ICP (Tempstar / Heil) RGS101HSBA0AAAA, available as a 30 Amp (OEM #1178074) or 40 Amp (OEM #1178211) unit with a 24-volt coil. The contactor is the high-voltage switch that powers the compressor and condenser fan motor when the thermostat calls for cooling; the 24V control signal energizes the coil, which pulls the contacts closed to deliver line voltage to the system. Contactors are a leading cause of no-cool calls — pitted or welded contacts, a chattering coil, or burned terminals all prevent the unit from starting reliably. Replacing it with the correct OEM-rated contactor restores clean, dependable switching.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-pole definite purpose contactor
Coil Voltage 24V
Contact Rating 30A or 40A
Poles 2
Brand ICP / Tempstar / Heil

Compatibility

Fits the ICP Tempstar Heil RGS101HSBA0AAAA and related ICP-family units. Match the amp rating (30A or 40A) and confirm the 24V coil against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Unfasten the old contactor and transfer wires one at a time to avoid mix-ups.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan start.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Buzzing or chattering coil
  • System won't start or starts intermittently
  • Melted or discolored terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101HSBA0AAAA — 30A & 40A 24V Options | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101HSBA0AAAA — 30A & 40A 24V Options | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101HSBA0AAAA — 30A & 40A 24V Options | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online