Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor for RGS101HSAA0AAAA — 30A/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RGS101HSAA0AAAA — 30A/40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole definite-purpose contactor for the ICP / Tempstar / Heil RGS101HSAA0AAAA gas furnace system. The contactor is an electrically operated switch that closes its main contacts when the 24-volt control coil is energized by the thermostat, sending line voltage to the compressor and condenser fan motor. Available in 30-amp (part 1178074) and 40-amp (part 1178211) ratings, both use a 24V coil. A failing contactor is one of the most common causes of an outdoor unit that won't start, chatters, or runs continuously. Burned, pitted, or welded contacts and a buzzing or dead coil are clear signs of wear.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V
Fitment OEM Replacement

Compatibility

Engineered for the ICP RGS101HSAA0AAAA and shared across the Tempstar, Heil, Comfortmaker, and Day & Night family of gas furnaces and matched outdoor units that use a 24V-coil 2-pole contactor. Verify your existing coil voltage (24V) and amp rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel on the condenser or furnace cabinet.
  3. Document — Photograph all line and low-voltage wiring before disconnecting anything.
  4. Remove — Note terminal positions, disconnect the line, load, and 24V coil leads, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contacts pull in on a call for cooling/heating and the unit runs.

Signs You Need a Replacement

  • Outdoor unit hums but won't start, or fails to start at all
  • Loud chattering or buzzing from the contactor
  • Visibly pitted, burned, or welded-together contacts
  • Compressor or fan runs nonstop even when the thermostat is satisfied

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101HSAA0AAAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101HSAA0AAAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101HSAA0AAAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online