ICP 2-Pole Contactor for RGS101HDAA0AAAA — 30A/40A 24V Coil | Ships Today
ICP

ICP 2-Pole Contactor for RGS101HDAA0AAAA — 30A/40A 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite purpose contactor switches line voltage to the compressor and condenser fan motor in your ICP RGS101HDAA0AAAA. When the thermostat sends a 24V signal, the coil energizes and pulls the contacts closed to start the outdoor unit. Offered in 30A (part 1178074) and 40A (part 1178211) versions, both with a 24-volt coil, this contactor is built to survive the repeated high-inrush load of compressor starts. Pitted or welded contacts are a leading cause of no-cool calls — the unit either fails to start or refuses to shut down.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-Pole Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30A or 40A
Coil Voltage 24 VAC
Poles 2

Compatibility

Built for the ICP RGS101HDAA0AAAA and the wider Tempstar/Heil/Comfortmaker lineup of condensing equipment running a 24V control circuit. Match the amp rating of your existing contactor, or step up to 40A for extra margin, and confirm the coil is 24V.

Installation Guide

  1. Safety First — Pull the outdoor disconnect and verify zero voltage across L1 and L2 with a multimeter.
  2. Access — Remove the condenser service panel to reach the control compartment.
  3. Document — Photograph all wiring and terminal positions before disconnecting.
  4. Remove — Transfer the line, load, and 24V coil leads one at a time to the new contactor.
  5. Install — Mount the new contactor in the same orientation and reconnect each wire per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no buzzing.

Signs You Need a Replacement

  • Outdoor unit hums but won't start
  • Burned, pitted, or welded contacts
  • Chattering or buzzing on a call for cooling
  • Compressor won't shut off due to welded contacts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101HDAA0AAAA — 30A/40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101HDAA0AAAA — 30A/40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101HDAA0AAAA — 30A/40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.