This genuine OEM 2-pole contactor for the ICP RGS091HFAA0AAAA is offered in 30-amp (part 1178074) and 40-amp (part 1178211) ratings, both with a 24-volt control coil. The contactor is the electrically-operated switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V coil is energized, the two power poles close and pass line voltage to the load; when the call ends, the contactor opens and de-energizes the system. Contactors are high-wear components — their contacts arc every cycle, eventually pitting, welding, or chattering. Replacing a worn contactor restores clean, reliable switching and prevents nuisance no-cool calls, compressor short-cycling, and burnt contact damage.

Specifications

Spec Value
30A Part Number 1178074
40A Part Number 1178211
Type 2-Pole Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Coil Voltage 24V
Poles 2
Amperage 30A or 40A
Fitment OEM

Compatibility

Fits the ICP/Heil/Tempstar RGS091HFAA0AAAA and similar units. Match the amperage to your original contactor (30A or 40A) and confirm the coil is 24V before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew the old contactor from its mounting.
  5. Install — Mount the new contactor, land each wire on the matching terminal per your photo, and confirm tight connections.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Burnt, pitted, or welded contacts
  • Chattering or buzzing when energized
  • Compressor/fan won't start despite a cooling call
  • Contactor won't drop out, leaving the unit running

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091HFAA0AAAA — 30A & 40A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091HFAA0AAAA — 30A & 40A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091HFAA0AAAA — 30A & 40A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online