This OEM 2-pole definite purpose contactor switches line power to the compressor and condenser fan in your ICP RGS150LDAA0AKAA unit. Energized by a 24V control signal from the thermostat, its coil pulls the contacts closed to start the outdoor unit. Available in 30 amp (part 1178074) and 40 amp (part 1178211) ratings, both with a 24V coil and two poles. Contactors are a common failure point: contacts pit and burn from constant arcing, and the coil can stick or chatter, leaving the AC unable to start or stop. Replacing a worn contactor restores reliable, clean switching.

Specifications

Spec Value
Part Number 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Amperage 30A or 40A
Coil Voltage 24V
Poles 2
Fitment OEM

Compatibility

Fits the ICP / Tempstar / Heil RGS150LDAA0AKAA and similar condensing units using a 2-pole 24V contactor. Match the amp rating (30A or 40A) to your original part before ordering.

Installation Guide

  1. Safety First — Disconnect power, verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical access panel.
  3. Document — Photo all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect the wires, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor, transfer each wire to the matching terminal per photo, and confirm tight connections.
  6. Test — Restore power, call for cooling, and verify the contacts pull in and the unit starts.

Signs You Need a Replacement

  • Outdoor unit won't start or won't shut off
  • Buzzing, humming, or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Visible arcing or melted housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150LDAA0AKAA — OEM Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150LDAA0AKAA — OEM Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150LDAA0AKAA — OEM Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online