This genuine OEM 2-pole definite purpose contactor for the ICP / Heil / Tempstar RGS150HSCA0AAAA is available in 30 amp (part 1178074) and 40 amp (part 1178211) ratings, both with a 24-volt control coil. The contactor is the electrically operated switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. The 24V coil pulls the two poles closed to pass line voltage to the load. Contactors wear out from millions of switching cycles, arcing, and pitting — burned or welded contacts cause a unit that won't start, won't shut off, or chatters. Installing a fresh OEM contactor restores reliable, clean switching.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-Pole Definite Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Contact Rating 30A or 40A
Coil Voltage 24 VAC
Poles 2
Fit OEM — exact replacement

Compatibility

Fits the ICP RGS150HSCA0AAAA and related Heil, Tempstar, and Comfortmaker units. Match the amp rating (30A vs 40A) to your failed contactor; both share the 24V coil and 2-pole configuration.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage across all terminals with a multimeter.
  2. Access — Remove the electrical/control panel cover.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Unit won't start or condenser fan and compressor stay off on a cooling call
  • Loud buzzing, humming, or chattering from the contactor
  • Burned, pitted, or welded contacts that won't open
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HSCA0AAAA — OEM 1178074 1178211 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HSCA0AAAA — OEM 1178074 1178211 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HSCA0AAAA — OEM 1178074 1178211 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.