Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor 30A & 40A 24V for RGS091HTBB0AAAA — Definite Purpose | Ships Today
ICP

ICP 2-Pole Contactor 30A & 40A 24V for RGS091HTBB0AAAA — Definite Purpose | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor for the ICP RGS091HTBB0AAAA system is available in 30A (P/N 1178074) and 40A (P/N 1178211) ratings, both with a 24V control coil. The contactor is the electromechanical switch that energizes the compressor and condenser fan when the thermostat calls for cooling. When the 24V coil is energized, the two poles close and pass line voltage to the load. Pitted, welded, or chattering contacts cause hard starting, intermittent cooling, or a system that won't shut off. Replacing a worn contactor restores clean, reliable switching.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-Pole Definite Purpose Contactor
Coil Voltage 24V
Amp Rating 30A / 40A
Poles 2
Brand ICP (Heil / Tempstar)
Fitment OEM Replacement

Compatibility

Fits the ICP/Heil/Tempstar RGS091HTBB0AAAA and compatible condensing units. Match the amp rating to your original contactor — select 30A or 40A as required by your unit's nameplate.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel.
  3. Document — Photo all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and detach the wires, then unfasten the old contactor.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor energizes.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Loud chattering or buzzing when engaged
  • Compressor or condenser fan fails to start
  • System won't shut off when satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091HTBB0AAAA — Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091HTBB0AAAA — Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091HTBB0AAAA — Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online