Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor 30A & 40A 24V Coil for RHS090H0AA0AAAA | Ships Today
ICP

ICP 2-Pole Contactor 30A & 40A 24V Coil for RHS090H0AA0AAAA | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor is the main switching relay for the ICP / Heil / Tempstar RHS090H0AA0AAAA. It is offered in both 30-amp (OEM 1178074) and 40-amp (OEM 1178211) ratings, each with a 24V control coil. The contactor uses the low-voltage 24V signal from the thermostat to close its line-voltage contacts and energize the compressor and condenser fan motor. Contacts are a wear item: every start cycle arcs across them, and over time they pit, burn, or weld. A failing contactor causes hard starts, chatter, a humming outdoor unit that won't run, or a unit that won't shut off. Choose the amp rating that matches the contactor currently installed in your unit.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite-purpose contactor
Poles 2-pole
Contact Rating 30A or 40A
Coil Voltage 24V
Brand ICP / Heil / Tempstar

Compatibility

Fits the ICP RHS090H0AA0AAAA and shared Heil, Tempstar, and Comfortmaker condensing units using a 2-pole 24V contactor. Confirm whether your unit uses the 30A or 40A version before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit service panel.
  3. Document — Photograph every wire on the contactor before disconnecting.
  4. Remove — Note line, load, and 24V coil terminals, then transfer wires one at a time or label them; unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan energize on a cooling call.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan don't start
  • Visibly pitted, burned, or welded contacts
  • Buzzing or chattering at the contactor
  • Unit won't shut off when the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS090H0AA0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS090H0AA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS090H0AA0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online