Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole Contactor 30A 24V Coil for RHS072S0XB0AAAA | Ships Today
ICP

ICP 2-Pole Contactor 30A 24V Coil for RHS072S0XB0AAAA | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite-purpose contactor (OEM 1178074) is the primary switching relay for the ICP / Heil / Tempstar RHS072S0XB0AAAA. Its 24V control coil receives the low-voltage call from the thermostat and closes line-voltage contacts to energize the compressor and condenser fan. Contacts wear with every cycle — arcing pits, burns, or welds them over time. A failing contactor shows up as an outdoor unit that hums but won't start, chatter, hard starts, or a unit that won't shut off after the thermostat is satisfied. This is an exact-fit OEM replacement with a 24V coil and 30A contact rating.

Specifications

Spec Value
OEM Part Number 1178074
Type Definite-purpose contactor
Poles 2-pole
Contact Rating 30A
Coil Voltage 24V
Brand ICP / Heil / Tempstar

Compatibility

Fits the ICP RHS072S0XB0AAAA and shared Heil, Tempstar, and Comfortmaker condensing units using a 2-pole 30A 24V contactor. Confirm the amp rating on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit service panel.
  3. Document — Photograph all wiring on the contactor before disconnecting.
  4. Remove — Transfer or label line, load, and 24V coil wires one at a time, then unscrew the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan run on a cooling call.

Signs You Need a Replacement

  • Outdoor unit hums but won't start
  • Pitted, burned, or welded contacts
  • Buzzing or chattering contactor
  • Unit won't shut off when cooling demand ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS072S0XB0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS072S0XB0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS072S0XB0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online