Genuine OEM definite purpose contactor for the ICP/Tempstar/Heil RH5320362 condensing unit, available as the 2-pole 40A (part number 1280460) or 1-pole 30A (part number 1280004) configuration. The contactor is the electrically operated switch that energizes the compressor and condenser fan whenever the 24V thermostat circuit calls for cooling. Over time the contacts pit, burn, or weld, causing a unit that won't start, won't stop, hums, chatters, or trips the breaker. Both versions use a 24V coil and are sized to the load they switch.

Specifications

Spec Value
Part Numbers 1280460, 1280004
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole (40A) / 1-Pole (30A)
Contact Rating 40 Amps / 30 Amps
Coil Voltage 24V
Fits Model RH5320362

Compatibility

Factory replacement for the ICP, Tempstar, Heil, and Comfortmaker RH5320362. Match your existing contactor's pole count and amp rating — 2-pole 40A (1280460) or 1-pole 30A (1280004) — and confirm the 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and outdoor disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser's electrical service panel.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Transfer the line, load, and 24V coil wires one at a time, then unscrew the old contactor.
  5. Install — Mount the new contactor and reconnect each wire exactly as photographed.
  6. Test — Restore power and confirm the contacts pull in and the compressor and fan start.

Signs You Need a Replacement

  • Burnt, pitted, or welded contacts
  • Loud humming or chattering at the contactor
  • Compressor and fan won't engage with a 24V signal present
  • Unit runs nonstop or trips the breaker on startup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RH5320362 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RH5320362 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RH5320362 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.