Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 40A Contactor for RGX036KRCA0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 40A Contactor for RGX036KRCA0AAA — 24V Coil | Ships Today

SKU: 1176763-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 40-amp contactor (part number 1176763) is the high-voltage switching relay for the ICP / Tempstar / Heil RGX036KRCA0AAA system. When the 24V control circuit energizes the contactor coil, the contacts pull in and pass line voltage to the compressor and/or fan motor; when the call ends, the contacts open and cut power. Rated at 40A, it handles the inrush and running loads of the unit. Contactors are wear items — the silver contacts pit, burn, and eventually weld shut or fail to close, while the coil can burn out. Symptoms include a unit that won't start, won't shut off, chatters, or buzzes loudly. A fresh contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1176763 (CONTACTOR 40A)
Type Definite Purpose Contactor, 2-Pole
Contact Rating 40 Amps
Coil Voltage 24V AC
Brand ICP / Tempstar / Heil
Fit OEM Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGX036KRCA0AAA and related RGX-series units using a 2-pole 40A, 24V-coil contactor. Verify pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer one wire at a time or label each, then unscrew and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect every wire to the matching terminal per your photos.
  6. Test — Restore power, initiate a call, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Unit won't start or won't shut off
  • Loud buzzing, chattering, or humming at the contactor
  • Pitted, burned, or welded contacts
  • Coil that no longer pulls the contacts in

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGX036KRCA0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGX036KRCA0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGX036KRCA0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online