OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 2-pole definite-purpose contactor (part #1178074 / #1178211) is the electrical switch that energizes the compressor and condenser fan motor in your ICP RGS121HDCA0AAA system. When the 24V control signal reaches the coil, the contactor pulls in and closes the line-voltage contacts that power the outdoor unit. Rated for 40A at 24V coil voltage, it handles the high inrush current of compressor start-up cycle after cycle. Failure symptoms include a unit that won't start, a buzzing or chattering outdoor unit, pitted or welded contacts, and a compressor that runs continuously because the contacts have fused closed.
| Spec | Value |
|---|---|
| Part Number | 1178074 / 1178211 |
| Type | 2-Pole Definite Purpose |
| Brand | ICP (Heil / Tempstar) |
| Amp Rating | 40A |
| Coil Voltage | 24V |
Designed for the ICP / Heil / Tempstar RGS121HDCA0AAA gas furnace and matched condensing units. Always confirm your existing contactor's pole count, amp rating, and coil voltage before installing.
Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.