Overview

This OEM definite-purpose contactor (part 1178211) for the ICP RGS091HTCA0AAA is a 2-pole, 40 amp unit with a 24-volt coil. The contactor is the electrically controlled switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling. Its 24V coil pulls in the contacts to pass line voltage to the load. Contactors fail from arcing, pitted or welded contacts, and burned coils — leading to a system that won't start, chatters, or won't shut off. Replacing a worn contactor restores reliable, quiet switching and protects downstream motors.

Specifications

Spec Value
Part Number 1178211
Type 2-Pole Definite Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Contact Rating 40 Amps
Coil Voltage 24 VAC
Poles 2
Fitment OEM Replacement

Compatibility

Designed for the ICP RGS091HTCA0AAA and compatible Heil, Tempstar, and Comfortmaker systems using a 2-pole 40A 24V coil contactor (OEM 1178211).

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect wires, then unfasten the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo (line, load, and coil terminals).
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan start.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Buzzing, chattering, or contactor won't pull in
  • System won't start or won't shut off
  • Visible arcing or melted coil/housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091HTCA0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091HTCA0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091HTCA0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.