This OEM 2-pole, 40-amp definite purpose contactor (OEM 1178211) is the high-current switch that powers the compressor and condenser fan motor on your ICP/Heil/Tempstar RGS091HRCB0AAA packaged unit. A 24V control coil energizes on a cooling call, pulling the contacts closed to feed line voltage to the loads. As one of the most frequently cycled components, the contactor's contacts pit and erode over time. Symptoms of failure include a unit that won't start, buzzing or chattering at the relay, or contacts that weld closed and leave the compressor running continuously.

Specifications

Spec Value
Part Number 1178211
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 2-Pole
Contact Rating 40A
Coil Voltage 24V

Compatibility

Direct fit for ICP RGS091HRCB0AAA and shared across many Heil, Tempstar, Comfortmaker, and ICP-family packaged and condensing units that use a 2-pole 40A 24V-coil contactor. Confirm amperage and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the control/service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Move one wire at a time to the new part, or label leads, then unscrew the old contactor.
  5. Install — Mount the new 40A contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and the compressor/fan run.

Signs You Need a Replacement

  • Unit won't start or starts intermittently
  • Buzzing, humming, or chattering at the relay
  • Pitted, burned, or welded contacts
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091HRCB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091HRCB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091HRCB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.