Overview

This is the OEM 2-pole, 40-amp definite-purpose contactor with a 24V coil (part number 1149653) for the ICP / Tempstar / Heil YJ060GA2. The contactor is the high-current relay that powers the outdoor unit. When the thermostat calls for cooling or heating, the 24V control coil pulls in the contactor, closing both poles to send line voltage to the compressor and condenser fan motor. Because it switches every cycle, the contactor is a wear item: its silver contacts pit, burn, and weld over time. A failing 2-pole 40A contactor causes the outdoor unit to chatter, hum, fail to start, or — when the contacts weld shut — run continuously even after the thermostat is satisfied.

Specifications

Spec Value
Part Number 1149653
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 40 Amp
Coil Voltage 24V
Fits Model YJ060GA2
Application AC compressor / condenser fan

Compatibility

Factory replacement contactor for the ICP Tempstar Heil YJ060GA2 outdoor unit and equivalent ICP-family condensing units that originally used the 2-pole 40A part 1149653. Verify pole count (2), amp rating (40A), and coil voltage (24V) against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the outdoor unit's control-box service panel.
  3. Document — Photograph all line, load, and 24V coil connections before removing any wires.
  4. Remove — Label and disconnect the leads, unscrew the contactor from its mounting bracket, and lift out the old part.
  5. Install — Mount the new 1149653 contactor, then reconnect every line, load, and 24V coil wire exactly as photographed.
  6. Test — Restore power and run a cooling call; confirm the contactor pulls in cleanly and the compressor and fan start without chatter.

Signs You Need a Replacement

  • Outdoor unit hums or chatters but will not start
  • Burned, pitted, or welded contacts
  • Compressor keeps running after the thermostat is satisfied
  • Buzzing 24V coil or intermittent operation

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ060GA2 — OEM 1149653 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ060GA2 — OEM 1149653 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ060GA2 — OEM 1149653 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online