Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Definite Purpose Contactor for RGS214HDBEAABTA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Definite Purpose Contactor for RGS214HDBEAABTA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite purpose contactor is the switching relay that energizes the compressor and condenser fan motor on your ICP Tempstar/Heil RGS214HDBEAABTA system. When the thermostat calls for cooling, a 24-volt signal pulls in the contactor coil, closing the line-voltage contacts that deliver power to the outdoor unit. This listing covers the 2-pole 30-amp contactor (OEM 1171554) and the 3-pole 40-amp version (OEM 1172449), both with a 24V coil. A failed contactor is one of the most common no-cooling complaints — pitted, burned, or welded contacts and a chattering or dead coil are classic symptoms.

Specifications

Spec Value
OEM Part Numbers 1171554 (2P), 1172449 (3P)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole / 3-Pole
Contact Rating 30A (2P) / 40A (3P)
Coil Voltage 24V

Compatibility

Engineered for the ICP Tempstar Heil RGS214HDBEAABTA and other ICP-family condensing units using a 24V-coil definite purpose contactor. Confirm pole count and amp rating against the original before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line and 24V wire positions before disconnecting.
  4. Remove — Note terminal locations, transfer one wire at a time, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and verify the contactor pulls in smoothly on a cooling call with no chatter.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan won't start
  • Burned, pitted, or welded contacts
  • Buzzing or chattering coil
  • Contactor stuck closed — unit runs even with thermostat off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS214HDBEAABTA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS214HDBEAABTA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS214HDBEAABTA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online