The OEM 1178074 is a 2-pole, 30-amp definite purpose contactor with a 24-volt coil for the ICP/Heil/Tempstar RHS048H0BB0AAAA. It is the high-voltage relay that switches line power to the compressor and condenser fan whenever the thermostat sends a 24V signal to the coil. Contactor failure is one of the most common no-cool service calls: pitted or welded contacts, a chattering coil, or contacts that won't pull in all leave the outdoor unit dead or buzzing. The 30A rating and 24V coil make this a direct OEM-spec replacement.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP (Heil / Tempstar / Comfortmaker)
Fitment OEM Direct Replacement

Compatibility

Direct OEM fit for the RHS048H0BB0AAAA and other ICP-family condensing/packaged units calling for a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage match your old contactor.

Installation Guide

  1. Safety First – Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the service panel to expose the contactor in the control box.
  3. Document – Photograph every line, load, and 24V coil connection before disconnecting.
  4. Remove – Move wires one at a time to the new contactor, or label them, then unscrew the old contactor from its mount.
  5. Install – Mount the new contactor, transfer line/load leads to the matching poles, and connect the 24V leads to the coil terminals per your photo.
  6. Test – Restore power and confirm the contactor pulls in cleanly on a cooling call with no chatter.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start.
  • Pitted, burned, or welded contacts.
  • Coil won't pull the contacts in on a 24V signal.
  • Intermittent compressor/fan operation from dirty contacts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS048H0BB0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS048H0BB0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS048H0BB0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.