Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RHS150S0BA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RHS150S0BA0AAAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole 30-amp definite purpose contactor (part number 1178074) with a 24V coil is the switching relay for the ICP Tempstar Heil RHS150S0BA0AAAA condensing unit. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor and condenser fan motor. Pitted or welded contacts are one of the most common no-cool failures. Symptoms of a failing contactor include a humming or buzzing condenser, a compressor that will not start, chattering contacts, or a unit that keeps running after the thermostat is satisfied because the contacts have welded shut.

Specifications

Spec Value
Part Number 1178074
Type Definite purpose contactor
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24 VAC
Brand ICP (Tempstar / Heil)
Fitment OEM exact-fit

Compatibility

Designed for the ICP / Tempstar / Heil RHS150S0BA0AAAA and other R-series condensing units that use a 2-pole 30A 24V contactor. Also fits compatible Comfortmaker and Arcoaire units sharing this part number.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel on the condensing unit.
  3. Document — Photo every line, load, and 24V wire before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan start.

Signs You Need a Replacement

  • Buzzing or humming contactor that won't pull in
  • Pitted, burned, or welded contacts
  • Compressor won't start on a cooling call
  • Unit keeps running after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS150S0BA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS150S0BA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS150S0BA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online