This is the genuine OEM 2-pole definite-purpose contactor with a 24-volt coil (Part No. 1178074, "CONTACTOR 2P 30A 24V") for the ICP/Tempstar/Heil RHS120H0CB0AAA heat pump. The contactor is the high-voltage switch that energizes the compressor and outdoor fan motor when the 24V control signal calls for operation. A 40-amp version (Part No. 1178211, "CONTACTOR 2P 40A 24V") is also used on this platform. Contactors fail from arcing, pitted or welded contacts, and burned coils — a failed contactor leaves the outdoor unit dead, buzzing, or chattering on a call for cool or heat.
| Spec | Value |
|---|---|
| Part Number | 1178074 (30A) |
| Alternate | 1178211 (40A) |
| Type | 2-pole definite purpose contactor |
| Coil Voltage | 24 VAC |
| Contact Rating | 30A (40A option) |
| Poles | 2 |
| Brand | ICP / Tempstar / Heil |
| Fits Model | RHS120H0CB0AAA |
| Fitment | OEM direct replacement |
Fits the ICP RHS120H0CB0AAA heat pump and shared ICP/Tempstar/Heil/Comfortmaker condensing units. Match the amp rating (30A or 40A) to your original contactor; the higher-rated unit is an acceptable upgrade as long as the footprint and 24V coil match.
Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.