Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RHS102S0BB0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RHS102S0BB0AAAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite purpose contactor (part number 1178074) is the primary switching relay for the ICP RHS102S0BB0AAAA heat pump. The contactor uses a 24-volt control coil to energize the compressor and condenser fan motor whenever the thermostat calls for cooling or heating. When the coil pulls in, the contacts close and pass line voltage to the outdoor unit. A failed or pitted contactor is one of the most common reasons an outdoor unit stops running, hums, or chatters. Typical failure symptoms include a buzzing or clicking contactor, burnt or welded contacts, an outdoor fan and compressor that will not start, or a unit that runs continuously because the contacts have welded shut.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V

Compatibility

Engineered as a direct OEM replacement for the ICP / Tempstar / Heil RHS102S0BB0AAAA heat pump. The 2-pole 30A 24V configuration is also a common service part across many ICP-family condensing units and heat pumps of similar tonnage.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit's service/access panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting anything.
  4. Remove — Note terminal positions, disconnect the wires, and unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan start on a call for cooling.

Signs You Need a Replacement

  • Loud buzzing, humming, or chattering from the contactor
  • Burnt, pitted, or melted contact surfaces
  • Outdoor compressor and fan fail to start on a cooling call
  • Contacts welded shut, causing the unit to run nonstop

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS102S0BB0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS102S0BB0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS102S0BB0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online