Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RHS102S0AA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RHS102S0AA0AAAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite-purpose contactor (part 1178074) is the electrical switch that energizes the compressor and condenser fan motor on your ICP RHS102S0AA0AAAA heat pump. When the thermostat calls for cooling or heating, the 24V coil pulls the contactor closed, sending line voltage to the compressor. Contactors are one of the most common HVAC failure points because the contacts arc and pit every cycle. Symptoms of a failing contactor include a unit that won't start, a loud chattering or buzzing at the contactor, contacts that weld shut (leaving the compressor running continuously), or pitted/burnt contact points. Installing a fresh OEM-rated 30A contactor restores clean switching and protects your compressor from low-voltage and chattering damage.

Specifications

Spec Value
OEM Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil RHS102S0AA0AAAA heat pump and compatible RHS102-series condensing units using a 2-pole, 24V-coil contactor. Verify your existing contactor's amp rating and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the contactor.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew the old contactor from its mounting.
  5. Install — Mount the new 30A contactor and reconnect line, load, and 24V coil leads exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a thermostat call with no chatter.

Signs You Need a Replacement

  • Compressor and condenser fan won't start on a cooling/heating call
  • Loud chattering or buzzing noise at the contactor
  • Pitted, burnt, or welded contact points
  • Contactor stuck closed, leaving the compressor running nonstop

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS102S0AA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS102S0AA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS102S0AA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online