This OEM 2-pole definite-purpose contactor is the switching relay that energizes the compressor and condenser fan in your ICP (Tempstar / Heil / Comfortmaker) RHS102L0CA0AAA heat pump. When the thermostat calls for cooling or heating, the 24V control coil pulls the contacts closed, sending line voltage to the outdoor unit. Rated for 30A and 40A loads at a 24-volt coil, it handles the high inrush of compressor start-up cycle after cycle. Failure symptoms include a humming or chattering outdoor unit, contacts that weld closed (unit won't shut off), pitted or burned contacts, or an outdoor unit that won't start at all even though the air handler runs.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil / Comfortmaker
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V

Compatibility

Engineered for the ICP RHS102L0CA0AAA heat pump condenser and shared across the Tempstar, Heil, and Comfortmaker family that use the same outdoor platform. Always confirm your existing contactor's pole count and amp/coil rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker; verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Note wire positions (L1/L2, T1/T2, coil terminals), pull the spade connectors, and unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor/fan start.

Signs You Need a Replacement

  • Loud humming, buzzing, or chattering from the outdoor unit
  • Contacts visibly pitted, burned, or welded together
  • Outdoor unit runs continuously and won't shut off
  • Compressor and fan won't start despite a thermostat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS102L0CA0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS102L0CA0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS102L0CA0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.