Overview

This genuine OEM 2-pole, 30-amp definite-purpose contactor (part #1178074, CONTACTOR 2P 30A 24V) is the main switching relay for the ICP/Tempstar/Heil RHS072S0CB0AAA heat pump. When the 24V control circuit energizes the coil, the contactor closes its two 30A poles to deliver line voltage to the compressor and condenser fan motor. With repeated cycling the contacts pit, burn, or weld and the coil can open — causing a unit that won't start, hums without pulling in, or runs continuously because the contacts have stuck closed. A worn contactor is one of the most common and inexpensive condenser failures to fix.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP (Tempstar / Heil)

Compatibility

Fits the ICP RHS072S0CB0AAA 6-ton heat pump condenser and other Tempstar, Heil, and Comfortmaker units specifying a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and 24V coil before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter on the line terminals.
  2. Access — Remove the condenser control-box service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer one wire at a time, or label leads and unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo, torqueing terminals snug.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor and fan energize.

Signs You Need a Replacement

  • Condenser hums but the compressor/fan won't start
  • Visible pitting, burning, or melted plastic on the contactor
  • Welded contacts causing the unit to run nonstop
  • Coil reads open on an ohm test or buzzes loudly

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS072S0CB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS072S0CB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS072S0CB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online